Different Polling Time
For NMS plotting, we need to polling for different interval of time? So availability for each node is monitored accordingly. For ExampleNode 1 will be monitored for 9 AM to 5 PM only.Node 2 will be...
View ArticleExport to PDF oddities
Hi there, I upgraded to 10.3 over the weekend and I've noticed a couple of issues with the Export to PDF functionality. First, although a thread in April said Chrome was not compatible with 'Export to...
View ArticleVirtual Servers not alerting when down or rebooted
We have P to V several servers and created several new virtual servers and added them to SW for monitoring and alerting. Now I find the (Server down or rebooted) alerts that used to work when the P to...
View ArticleInner workings of the Orion audit databases?
Hello, In lieu of granular unmanagement rights I have been tasked and thus working on a secure means of allowing for select people to modify the unmanagement details of specific nodes. My method will...
View ArticleOrion showing Hardware Health Sensors details incorrect reading of Critical...
This is what Orion is showing Power Supply Sw1, PS1 Normal, RPS NotExistNormal Sw1, PS2 Faulty, RPS NotExistNot FunctioningSw2, PS1 Normal, RPS NotExistNormalSw3, PS1 Faulty, RPS NotExistNot...
View ArticleOverall Hardware Status has state "could not poll"
Hi, As the title really, one of my switches has the above state, I have restarted the polling service on the server to no avail, I don't really want to delete the node and re-add it as it is one of our...
View ArticleUnable to get character return in custom report
I am using a custom SQL report, but am unable to get character returns to show in the web browser's reporting screen. The weird thing is when I preview/execute SQL query from report write, the...
View ArticlePull VMWare multi-site environment
Is there a way to choose what hosts to monitor in VMware Polling Settings?I have a multi-site environment that has DR guests and I do not want to monitor them.If I choose the vcenter it pulls all the...
View ArticleStop Alerts for volumes that have been over the threshold for 90 days
How to configure Alerts so if the Condition has been true for 90 days, stop alerting,? We monitor Volume space, with 85% threshold. If a drive has been at or above this threshold for more than 90 days,...
View Articlehow many maps does network atlas can hold?
I have been told by solarwinds engineer that I need to reduce the amount of maps to 50 maps. What is the amount of maps that network atlas allows to create? is there a limit?abilities
View ArticleCan you add back the checkboxes to remove lines from graphs?
I just upgraded to 10.5 and prior to that, I had checkboxes to remove lines from all the different graphs. It was really great and helpful when I wanted to see just one part of my network traffic...
View ArticleAll Solarwinds Databases seem to be severely fragmented and maintenance...
I have a dedicated SQL 2008R2 box for our Solarwinds deployment. It is a very robust server with twin 4 core Xeon processors, 32GB ram and solid state hard drives. I decided to drop the new APPInsight...
View ArticleNPM Evaluacion
Estimados instale la evaluacion de NPM pero no valida el usuario admin sin password.Lesw habra pasado este problema a uno de UdsSaludos
View ArticleReport Writer - Down Nodes with Event Time
Is it possible to create a report that generates currently down nodes with its event time.Ex. Node Name Event TimeDevice_A 22-April-2009 11:45:06 AM Thanks!
View ArticleIn Cisco devices, the Total Memory report incorrect
Hi, I realized that the Total Memory value in Solarwind reporter are incorrect. And the percentage of MEMORY Utilization may be incorrect also, because it take value of Used Memory divided to wrong...
View ArticleProblem with Network Atlas
Hello , My Orion Network Atlas was working fine but now suddenly when I try to edit the topology I get the following error "Connection to the Information Service has been lost and could not be...
View ArticleAPC UPS runtime problem
I created a poller for our APC SmartUPS which returns the remaining battery runtime - upsAdvBatteryRuntimeRemaining OID 1.3.6.1.4.1.318.1.1.1.2.2.3.0 - and tested it on our devices from within the...
View ArticleNPM 10.6 RC2 IS HERE - UNDP ON MAPS, NEW OPENSTREET MAPS, NEW REPORTING
I would like to say a big thanks to all who gave us a feedback after NPM 10.6 RC1 announcement. We fixed small bugs reported by our customer base and NPM 10.6 RC2 is ready to be installed on your...
View ArticleOverall Hardware Status has state "could not poll"
Hi, As the title really, one of my switches has the above state, I have restarted the polling service on the server to no avail, I don't really want to delete the node and re-add it as it is one of our...
View ArticleHaving Juniper and want to see VRFs in NPM?
We know that Juniper is widely used in your networks. If you would like to help us and accelerate the implementation process send me SNMP walks of your Juniper devices with VRF configs on them. All the...
View Article